OD Monitor control unit ODBox A
OD Monitor control unit ODBox A
It is a control unit of OD-MonitorA & S.
Main Application
●Cell density observation of bacterial in culturing●Cell density observation of pathogenic bacteria
●Cell observation of bacillus in culturing under anaerobic conditions which gas concentration is important
●Cell density observation of bacteria with slow multiplication rate
●Cell density observation of floating mammals cell (scheduled)
Features
Realized to measure the rotating turbidity culture by our original technology.
This unit calculates the turbidity by numerically analyzed "the relation between movement and the penetration light in the sample while rotating in Erlenmeyer flask".Set the Erlenmeyer flask size and shaking speed at the measurement.
Data can be saved in USB memory
It alarms you when it reaches the set OD value
It alarms you by buzzer when it reaches the set OD value(Possible to set by each unit)It can correct the gap of your spectrophotometer.
OD value may change by the measurement unit.The correction function makes the gap of your spectrophotometer within 15%.
The measurement unit is connected up to eight sets.The printer is also connected.
Specifications
Model | ODBox-A |
Display of (OD) value | Display of converted values from transmitted light volume of infrared ray (950nm) to OD600 of E.coli bacteria |
Measurement Range | 0.1 - 2.0(accuracy guarantee range 0.5 - 1.5) |
Correction for biological species other than E. coli bacteria and gap from spectrophotometer | Enter correction factors (0.01 - 2.55、initial value is 1.00) |
Correction allowance / Correction range | Within 15% (OD = 0.5 - 1.5) |
Interval | 1/5/10/30/60/120/240min |
Maximum Measurement Time | Internal memory : 360 points (*1) USB memory : Up to USB memory |
Maximum Connectable ODSensor-S | 8sets(2ch x 4), Measurement under all same conditions |
Interface for print output | RS-232C (*2) |
Interface for external storage medium | Port for USB2.0 flash memory (*3) |
Other Functions | Alarm function (alarm by buzzer at reached target OD) (*4) |
Dimensions | 153 x 220 x 127Hmm |
Standard Accessory | Flat cable (2m) x 1 |
(*1)Point = Total measurement time / Interval. The 360th point figure is to updated when it exceed 360 points.
(*2)The recommended cable is KRS-433XF07K made by SANWA SUPPLY and the recommended rollpaper printer is BL2-58NBJC made by SANEI DENKI corporation.
(*3)Some memory cannot be used with this unit even if it can be used with a personal computer.
(*4)If it reaches the target value, a buzzer may not immediately ring depending on setting of interval.
(*2)The recommended cable is KRS-433XF07K made by SANWA SUPPLY and the recommended rollpaper printer is BL2-58NBJC made by SANEI DENKI corporation.
(*3)Some memory cannot be used with this unit even if it can be used with a personal computer.
(*4)If it reaches the target value, a buzzer may not immediately ring depending on setting of interval.
●ODSensor-S is sold separately.