Pengukur Gas MacView IPR
PENGUKUR GAS MacView IPR
The MACView® IPR is a universal measuring system for gasses, vapours and solid (dust) particles. A extra unique feature is that the system is controlled and the visualisation is processed by a integrated webserver.
PENGUKUR GAS MacView IPR
With this system it is possible to follow facilities with a internet connection on one location, more office buildings, factory buildings or worldly spread production plants. The advantages are more then one. A Quality Assurance departement can check the performance of the air cleaning facility in a glance, or a Quality Control departement can monitor continuously the dust load in a packaging compartement. But also international operating companies which want to follow on a distance in different countries the performances of their production plants in real time, it is all possible.
PENGUKUR GAS MacView IPR
The MACView® IPR is build modular. In theory one can add as much sensors as available internet adresses. The system is build in a 19” housing. Every 19” housing can position 8 IPR cards with each 2 sensors. This means that with one 19” housing 16 sensors can be monitored at the same time. When the 19” housing is full, it is easy to add another housing in the rack.
TECHNICAL SPECIFICATION
Number of slots
|
8 slots can position 8 IPR cards in a 19”
housing, housing is 3U high
|
Number of
channels
|
2 channels on one IPR card
|
Number of
sensors
|
More than 80 sensors available for gasses,
vapours and fine dust particles, 3 wire 4-20mA-Combustibles - Toxic Gases -
Oxidizing Gases - Organic Solvents - CFC's (HCFC's en HFC's) - Indoor
Pollutants - Cooking Vapors – OxygenEvery sensor measures the following
values of a quantity : concentration, relative humidity and temperature
|
Type of sensors
|
206402: MACView®
Wall-mount sensor 4-20mA output, gas, RH and T206502: MACView®
Wall-mount EeX sensor 4-20mA output, gas, RH and T206304: MACView®
Particles Advanced sensor 4-20mA output, fine dust particles, RH and
T206305: MACView® Particles Advanced press fitting sensor
4-20mA output, fine dust particles, RH and T, suitable for ventilation
channels
|
Housing
material
|
High quality aluminium with anodising layer
|
Standards
|
NEN-EN-IEC 61000-6-1 t/m 4, CE, Ethernet
IEEE 802.3, TCP/IP, HTML en SMTP
|
Signals/warnings
|
ppm of mg/m³ and hysteresis adjustable on
relais (programmable for every function)Analogue output 4-20mA (programmable
for every function)E-mail adjustableSeveral status LED’s : power, failure,
RX, TX, Collision, relais 1, relais 2
|
Acceptance of
warnings
|
With accept button on front side or through
browser
|
Communication
protocol
|
TCP/IP over IEEE 802.3 Ethernet, (UTP
connection with 8 wires)
|
Registration
|
Internal database with date and time clock
|
Sensor inputs
|
4-20mA suitable for long range with
transmission protocol
|
Sensor
connections
|
3-wire : power, 0V, signal4-wire : power,
0V, signal, signal 0V (reference)
|
Inputs
|
1 digital input (potential free)
|
Outputs
|
2 analogue outputs (0-10V, 0-20mA or 4-20mA,
adjustable throug the software) mA outputs are up to a load of 400Ohm at 12V2
digital outputs (potential free relais 230V, 1A) for concentration warning1
digital output (potential free relais 230V, 1A) for internal failure warning
|
Service
connection
|
RS232 interface
|
Powerconnection
|
In: 230 VAC
Out: 12V, 150W for external sensors |
Operating
temperature sensors
|
-30 / +80 degree Celcius, relative humidity
5 till 95%, not condensed
|
Operating
temperatureMACView® IPR
|
-10 / +50 degree Celcius, relative humidity
5 till 95%, not condensed
|
Software
|
Integrated in a autonomous webserverFor more
IPR systems a control tool is available. This tool is not neccesary when
using a small number of MACView® IPR systems
|
User interface
|
HTML pages in a browser and E-mail
|
DimensionsMACView®
IPR
|
Rack 3U, 19” housing W 482 x H 132 x D 266
mm
|
Mounting
|
In a cabinet frame rack suitable for 19”
housings
|
Silahkan klick tulisan merah dibawah ini!!!
SILAHKAN DOWNLOAD CATALOG PENGUKUR GAS MacView IPR KAMI